Central European Journal of Sport Sciences and Medicine

ISSN: 2300-9705     eISSN: 2353-2807    OAI    DOI: 10.18276/cej.2021.1-01
CC BY-SA   Open Access   DOAJ  DOAJ

Lista wydań / Vol. 33, No. 1/2021
Validity of an Inertial Measurement Unit System to Assess Lower-limb Kinematics during a Maximal Linear Deceleration

Autorzy: Alastair R. Jordan
School of Science Technology and Health, York St John University, Haxby Road Sports Park, York, YO31 8TA, United Kingdom

Howie J. Carson ORCID
Institute for Sport, Physical Education and Health Sciences, Moray House School of Education and Sport, The University of Edinburgh, United Kingdom

Brett Wilkie
School of Science Technology and Health, York St John University, Haxby Road Sports Park, York, YO31 8TA, United Kingdom

Damian J. Harper
Institute of Coaching and Performance, School of Sport and Health Sciences, University of Central Lancashire, United Kingdom
Słowa kluczowe: biomechanics braking IMU stopping Xsens
Data publikacji całości:2021
Liczba stron:12 (5-16)
Cited-by (Crossref) ?:

Abstrakt

This study examined the validity of an inertial measurement unit system for measuring lower-limb joint kinematics during linear decelerations. A male team athlete (age 36 years, stature 1.75 m, mass 80.0 kg) performed multiple linear decelerations, following 20 m runs at 50%, 75% and 100% self-perceived effort. Inertial measurement unit sensors were strapped to lower-limb segments and retroreflective markers were adhered to the lower-limbs for 3D optical motion analysis. Ground contact time, foot to centre of mass displacement (foot-COM), peak and minimum angle, mean angular velocity and range of motion at the ankle, knee and hip during the contact phases of each deceleration were determined. Measures were valid if a very large correlation (r ≥ 0.7) and small bias (effect size < 0.6) were evident. Following 50% effort, ground contact time, foot-COM and most hip and knee kinematics were valid. Ground contact time, foot-COM and knee flexion velocity and range of motion were valid following 75% efforts. Ground contact time and knee flexion velocity were valid following 100% effort. Therefore, the inertial measurement unit system tested can be used to assess temporal-spatial parameters during a deceleration regardless of the preceding effort, and hip and knee kinematics following low intensity running.
Pobierz plik

Plik artykułu

Bibliografia

1.Abt, G., Siegler, J.C., Akubat, I., Castagna, C. (2011). The effects of aconstant sprint-to-rest ratio and recovery mode on repeated sprint performance. The Journal of Strength & Conditioning Research, 25 (6), 1695–1702. https://doi.org/10.1519/JSC.0b013e3181dbdc06
2.Adesida, Y., Papi, E., McGregor, A.H. (2019). Exploring the role of wearable technology in sport kinematics and kinetics: Asystematic review. Sensors, 19, 1597. https://doi.org/10.3390/s19071597.
3.Balsom, P.D., Seger, J.Y., Sjödin, B., Ekblom, B. (1992). Physiological responses to maximal intensity intermittent exercise. European Journal of Applied Physiology and Occupational Physiology, 65 (2), 144–149. https://doi.org/10.1007/BF00705072
4.Blair, S., Duthie, G., Robertson, S., Hopkins, W., Ball, K. (2018). Concurrent validation of an inertial measurement system to quantify kicking biomechanics in four football codes. Journal of Biomechanics, 73 (1), 24–32. https://doi.org/10.1016/j.jbiomech.2018.03.031
5.Bloomfield, J., Polman, R., O’Donoghue, P. (2008). Deceleration and turning movements performed during FA Premier League soccer matches. In: T. Reilly, F. Korkusuz (eds.), Science and Football VI; the Proceedings of the Sixth World Congress on Science and Football (pp.174–181). Routledge.
6.Buchheit, M., Gray, A., Morin, J.-B. (2015). Assessing stride variables and vertical stiffness with GPS-embedded accelerometers: Preliminary insights for the monitoring of neuromuscular fatigue on the field. Journal of Sports Science & Medicine, 14 (4), 698 –701.
7.Camomilla, V., Bergamini, E., Fantozzi, S., Vannozzi, G. (2018). Trends supporting the in-field use of wearable inertial sensors for sport performance evaluation: Asystematic review. Sensors, 18, 873. https://doi.org/10.3390/s18030873
8.Carson, H.J., Collins, D., Richards, J. (2014). Intra-individual movement variability during skill transitions: Auseful marker? European Journal of Sport Science, 14 (4), 327–336. https://doi.org/10.1080/17461391.2013.814714
9.Cesar, G.M., Sigward, S.M. (2015). Dynamic stability during running gait termination: Differences in strategies between children and adults to control forward momentum. Human Movement Science, 43 (1), 138–145. https://doi.org/10.1016/j.humov.2015.08.005
10.Cesar, G.M., Sigward, S.M. (2016). Dynamic stability during running gait termination: Predictors for successful control of forward momentum in children and adults. Human Movement Science, 48 (1), 37–43. https://doi.org/10.1016/j.humov.2016.03.014
11.Chaouachi, A., Manzi, V., Chaalali, A., Wong, P., Chamari, K., Castagna, C. (2012). Determinants analysis of change-of-direction ability in elite soccer players. Journal of Strength & Conditioning Research, 26, 2667–2676. https://doi.org/10.1519/JSC.0b013e318242f97a
12.Cochrane, J.L., Lloyd, D.G., Buttfield, A., Seward, H., McGivern, J. (2007). Characteristics of anterior cruciate ligament injuries in Australian football. Journal of Science and Medicine in Sport, 10 (2), 96–104. https://doi.org/10.1016/j.jsams.2006.05.015
13.Coleman, A.E. (2001). Target and recovery times for speed training in baseball. Strength & Conditioning Journal, 23 (6), 7–8.
14.Dalen, T., Ingebrigtsen, J., Ettema, G., Hjelde, G.H., Wisloff, U. (2016). Player load, acceleration, and deceleration during forty-five competitive matches of elite soccer. Journal of Strength & Conditioning Research, 30 (2), 351–359. https://doi.org/10.1519/JSC.0000000000001063
15.Dos’Santos, T., Thomas, C., Comfort, P., Jones, P.A. (2018). The effect of angle and velocity on change of direction biomechanics: Anangle-velocity trade-off. Sports Medicine, 48 (10), 2235–2253. https://doi.org/10.1007/s40279-018-0968-3
16.Ferrari, A., Cutti, A.G., Garofalo, P., Raggi, M., Heijboer, M., Cappello, A., Davalli, A. (2010). First in vivo assessment of “Outwalk”: Anovel protocol for clinical gait analysis based on inertial and magnetic sensors. Medical & Biological Engineering & Computing, 48, 1–15. https://doi.org/10.1007/s11517-009-0544-y
17.Fleron, M.K., Ubbesen, N.C.H., Battistella, F., Dejtiar, D.L., Oliveira, A.S. (2019). Accuracy between optical and inertial motion capture systems for assessing trunk speed during preferred gait and transition periods. Sports Biomechanics, 18 (4), 366–377. https://doi.org/10.1080/14763141.2017.1409259
18.Green, B.S., Blake, C., Caulfield, B.M. (2011). Acomparison of cutting technique performance in rugby union players. Journal of Strength & Conditioning Research, 25 (10), 2668–2680. https://doi.org/10.1519/JSC.0b013e318207ed2a
19.Harper, D., Jordan, A., Kiely, J. (2021). Relationships between eccentric and concentric knee strength capacities and maximal linear deceleration ability in male academy soccer players. Journal of Strength & Conditioning Research, 35 (2), 465–472. https://doi.org/10.1519/JSC.0000000000002739
20.Harper, D., Kiely, J. (2018). Damaging nature of decelerations: Do we adequately prepare players? BMJ Open Sport and Exercise Medicine, 4, e000379. https://doi.org/10.1136/bmjsem-2018-000379
21.Hewit, J., Cronin, J., Button, C., Hume, P. (2011). Understanding deceleration in sport. Strength and Conditioning Journal, 33 (1), 47–52. https://doi.org/10.1519/SSC.0b013e3181fbd62c
22.Hopkins, W.G. (2002). Ascale of magnitudes for effect statistics. ANew View of Statistics, 502, 411. Retrieved from: https://sportsci.org/resource/stats/effectmag.html.
23.Kovacs, M.S., Roetert, E.P., Ellenbecker, T.S. (2008). Efficient deceleration: The forgotten factor in tennis-specific training. Strength and Conditioning Journal, 30 (6), 58–69. https://doi.org/10.1519/SSC.0b013e31818e5fbc
24.Krüger, A., Edelmann-Nusser, J. (2009). Biomechanical analysis in freestyle snowboarding: Application of afull-body inertial measurement system and abilateral insole measurement system. Sports Technology, 2 (1–2), 17–23. https://doi.org/10.1080/19346182.2009.9648494
25.Laudanski, A., Brouwer, B., Li, Q. (2013). Measurement of lower limb joint kinematics using inertial sensors during stair ascent and descent in healthy older adults and stroke survivors. Journal of Healthcare Engineering, 4 (4), 555–576. https://doi.org/10.1260/2040-2295.4.4.555
26.Mara, J.K., Thompson, K.G., Pumpa, K.L., Morgan, S. (2017). The acceleration and deceleration profiles of elite female soccer players during competitive matches. Journal of Science and Medicine in Sport, 20 (9), 867–872. https://doi.org/10.1016/j.jsams.2016.12.078
27.Nedergaard, N.J., Kersting, U., Lake, M. (2014). Using accelerometry to quantify deceleration during ahigh-intensity soccer turning manoeuvre. Journal of Sports Sciences, 32 (20), 1897–1905. https://doi.org/10.1080/02640414.2014.965190
28.Reenalda, J., Maartens, E., Homan, L., Buurke, J.J. (2016). Continuous three dimensional analysis of running mechanics during amarathon by means of inertial magnetic measurement units to objectify changes in running mechanics. Journal of Biomechanics, 49 (14), 3362–3367. https://doi.org/10.1016/j.jbiomech.2016.08.032
29.Robert-Lachaine, X., Mecheri, H., Larue, C., Plamondon, A. (2017). Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis. Medical and Biological Engineering and Computing, 55 (4), 609–619. https://doi.org/10.1016/j.jbiomech.2016.08.032
30.Roetenberg, D., Luinge, H., Slycke, P. (2009). Xsens MVN: Full 6DOF human motion tracking using miniature inertial sensors. Technical report. Xsens Technologies B.V.
31.Russell, M., Sparkes, W., Northeast, J., Cook, C.J., Love, T.D., Bracken, R.M., Kilduff, L.P. (2016). Changes in acceleration and deceleration capacity throughout professional soccer match-play. Journal of Strength & Conditioning Research, 30 (10), 2839–2844. https://doi.org/10.1519/JSC.0000000000000805
32.Seel, T., Raisch, J., Schauer, T. (2014). IMU-based joint angle measurement for gait analysis. Sensors, 14 (4), 6891–6909. https://doi.org/10.3390/s140406891
33.Spencer, M., Bishop, D., Dawson, B., Goodman, C. (2005). Physiological and metabolic responses of repeated-sprint activities. Sports Medicine, 35 (12), 1025–1044. https://doi.org/10.2165/00007256-200535120-00003
34.Spiteri, T., Nimphius, S., Hart, N.H., Specos, C., Sheppard, J.M., Newton, R.U. (2014). Contribution of strength characteristics to change of direction and agility performance in female basketball athletes. Journal of Strength & Conditioning Research, 28 (9), 2415–2423. https://doi.org/10.1519/JSC.0000000000000547
35.Wouda, F.J., Giuberti, M., Bellusci, G., Maartens, E., Reenalda, J., Van Beijnum, B.F., Veltink, P.H. (2018). On the validity of different motion capture technologies for the analysis of running. Paper presented at the 7th IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (Biorob), Enschede. https://doi.org/10.1109/BIOROB.2018.8487210
36.Zhang, J.-T., Novak, A.C, Brouwer, B., Li, Q. (2013). Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics. Physiological Measurement, 34 (8), N63–N69. https://doi.org/10.1088/0967-3334/34/8/N63